CMG-5T Compact
Compact Triaxial Accelerometer
Operator's guide
Part No. MAN-050-0004
Designed and manufactured by
Güralp Systems Limited
3 Midas House, Calleva Park
Aldermaston RG7 8EA
England
Proprietary Notice: The information in this manual is
proprietary to Güralp Systems Limited and may not be
copied or distributed outside the approved recipient's
organisation without the approval of Güralp Systems
Limited. Güralp Systems Limited shall not be liable for
technical or editorial errors or omissions made herein,
nor for incidental or consequential damages resulting
from the furnishing, performance, or usage of this
material.
Issue E 2011-05-05
Seitenansicht 0
1 2 3 4 5 6 ... 26 27

Inhaltsverzeichnis

Seite 1 - CMG-5T Compact

CMG-5T CompactCompact Triaxial AccelerometerOperator's guidePart No. MAN-050-0004Designed and manufactured byGüralp Systems Limited3 Midas House,

Seite 2 - Table of Contents

CMG-5T Compact3. Adjust the vertical screw until the output voltage reads zero.4. Repeat steps 2 and 3 for the N/S and E/W channels, (with the meter

Seite 3 - 1 Introduction

Operator's GuideThe current offset values will display. Once the process has completed the Scream! status window will display (in green):CENTERIN

Seite 4

CMG-5T Compact• To monitor the high-gain outputs, switch the dial to V, N/S or E/W HIGH VEL.• The V, N/S or E/W MASS POS settings are not applicable t

Seite 5 - 2 Installation

Operator's Guide3 CalibrationThe 5T Compact is supplied with a comprehensive calibration document and it should not normally be nece

Seite 6 - 2.2 Initial testing

CMG-5T Compactsignal into the sensor. This can be either a sine wave, a step function or broad-band noise, depending on your requirements. As well a

Seite 7 - 2.3 Installing the sensor

Operator's GuideCalibration Line for all three components. Other choices will not have a useful effect.3. Make any other choices you require a

Seite 8 - 2.3.1 Temporary installations

CMG-5T CompactNote that if you have used the Scale... option described above, you will need to take the scale factor into account to produce the corre

Seite 9 - 2.4.1 Manual offset removal

Operator's Guidecalibration by tilting the sensor by 90° and varying the calibration signal until it precisely compensates for

Seite 10

CMG-5T Compactsignal received from the instrument by a recording system with a differential input will be twice the tr

Seite 11 - 2.5.1 Signal meter

Operator's Guide3.4.3 Obtaining copies of the calibration packWe keep a copy of all calibration data that we send out. In the event that the cal

Seite 12 - 2.5.4 Banana sockets

CMG-5T CompactTable of Contents1 Introduction...

Seite 13 - 3 Calibration

CMG-5T Compact4 Inside the 5T CompactThe 5T Compact unit is constructed of hard-anodised aluminium with “O” rings throughout, ensuring a completely w

Seite 14

Operator's Guidesensitive detector. The accelerometer feedback loop is completed with a phase compensator and a feedback force trans

Seite 15

CMG-5T CompactThe normalising constant A is calculated at a normalising frequency value fm = 1 Hz, with s = j fm, where j = √–1. • H(s)

Seite 16

Operator's GuideFor distances up to 10 m, you can connect the sensor outputs using balanced screened twin lines terminated with a

Seite 17 - 3.4 The calibration pack

CMG-5T Compact5 Connector pinoutThe connector is a standard 26-pin “mil-spec” plug, conforming to MIL-DTL-26482 (formerly MIL-C-26482). A

Seite 18 - 3.4.2 Frequency response

Operator's GuideWiring details for the compatible socket, ***-16-26S, as seen from the cable end.May 2011 25

Seite 19 - From: [email protected]

CMG-5T Compact6 SpecificationsOutputs and responseLow gain output options 4g, 2g, 1g, 0.5g, 0.1gCorresponding high gain outputs0.4g, 0.2g, 0.1g, 0.05

Seite 20 - 4 Inside the 5T Compact

Operator's Guide7 Revision history2011-02-15 E Revised Offset removal section, updated connector pin out section.2009-11-24 D Updated block

Seite 21 - 4.1 The force transducer

Operator's Guide1 IntroductionThe CMG-5T Compact is a three-axis, strong-motion, force-feedback accelerometer in a sealed

Seite 22 - 4.2 Electrical connections

CMG-5T Compactsingle-ended output for 1 g (≈ 9.81 m/s2) input acceleration. The standard frequency pass band is flat to accelerati

Seite 23

Operator's Guide2 Installation2.1 Unpacking and packingThe CMG-5T Compact accelerometer is delivered in a single cardboard box with foam rubbe

Seite 24 - 5 Connector pinout

CMG-5T Compactwhich is also provided on the calibration sheet.2.2 Initial testingTo test the 5T Compact before installation, you will need a power so

Seite 25 - May 2011 25

Operator's Guide2.3 Installing the sensorYou will need a hard, clean surface such as a concrete floor, to install the 5T Compact. If you are i

Seite 26 - 6 Specifications

CMG-5T Compactinsulation slabs) with the joints between them sealed. A hole should be drilled for the connector. You can then

Seite 27 - 7 Revision history

Operator's Guideinstrument makes it suitable for use in hazardous environments where electrical discharges due to the build up of static charge c