CMG-3T
Triaxial Broadband Seismometer
Operator's guide
Part No. MAN-030-0001
Designed and manufactured by
Güralp Systems Limited
3 Midas House, Calleva Park
Aldermaston RG7 8EA
England
Proprietary Notice: The information in this manual is
proprietary to Güralp Systems Limited and may not be
copied or distributed outside the approved recipient's
organisation without the approval of Güralp Systems
Limited. Güralp Systems Limited shall not be liable for
technical or editorial errors or omissions made herein,
nor for incidental or consequential damages resulting
from the furnishing, performance, or usage of this
material.
Issue N 2009-07-06
Seitenansicht 0
1 2 3 4 5 6 ... 52 53

Inhaltsverzeichnis

Seite 1 - Operator's guide

CMG-3TTriaxial Broadband SeismometerOperator's guidePart No. MAN-030-0001Designed and manufactured byGüralp Systems Limited3 Midas House, Calleva

Seite 2 - Table of Contents

CMG-3Tpower will be supplied through the digitizer, which can also activate the sensor control lines.The breakout box also provides a CONTROL

Seite 3 - 1 Introduction

Operator's guideTemporary installations can be protected against spurious vibrations by• selecting a suitable site,• placing the instrument in a

Seite 4 - 1.1 Options

CMG-3TIf you cannot easily see the pointers, you should align the sensor using the north arrow on the handle. Howe

Seite 5 - Sensor control interface

Operator's guideyou are using one.7. Connect a 12 Volt power supply, either directly or through the breakout box or digitizer.8. Unlock the sens

Seite 6 - Sensor response

CMG-3T11.Ensure that the sensor cable is loose and that it exits the seismometer enclosure at the base of the instrument. This w

Seite 7 - 2 Installing the 3T

Operator's guide2. On granite or other hard bedrock, use an angle grinder to plane off the bedrock at the pit bottom so that it is flat and level

Seite 8 - Connections

CMG-3Tprepare a concrete mix with sand and fine grit, and pour it into the hole. Agitate (“puddle”) it whilst still liquid, to allow it to flow out an

Seite 9 - Signal output

Operator's guideSome installations introduce a layer of ceramic tiles between a rock or concrete plinth and the seismometer (left): However, no

Seite 10 - 2.2 Installation notes

CMG-3TBy following these guidelines, you will ensure that your seismic installation is ready to produce the highest quality data.2.5

Seite 11 - 2.3 Installing in vaults

Operator's guidecrushed rock, with a high proportion of rock flour and fine particles, makes excellent packing material. Alternativ

Seite 12

CMG-3TTable of Contents1 Introduction...31

Seite 13

CMG-3T3 Calibrating the 3T3.1 The calibration packAll Güralp sensors are fully calibrated before they leave the factory. Both absolute and relative ca

Seite 14 - 2.4 Installing in pits

Operator's guidePoles and zeroesMost users of seismometers find it convenient to consider the sensor as a “black box”, which produces an output s

Seite 15

CMG-3TFrequency response curvesThe frequency response of each component of the 3T is described in the normalised amplitude and phase plots provided. T

Seite 16 - Other installation methods

Operator's guide3.2 Calibration methodsVelocity sensors such as the 3T are not sensitive to constant DC levels, either as a result of their desig

Seite 17

CMG-3Tcalibration will be used to determine the complete sensor response in one action. Please refer to the digitizer's manual for information on

Seite 18 - 2.5 Installing in post-holes

Operator's guidetop left of the window or the cursor keys.Drag the calibration stream Cn up the Waveview window, so that it is at the top.4. If

Seite 19

CMG-3TMost data can be found on the calibration sheet for your sensor. Under Instrument response, you should fill in the sensor respons

Seite 20 - 3 Calibrating the 3T

Operator's guideinformation is present in higher-rate streams, they also include a large amount of high-frequency data which may

Seite 21 - Poles and zeroes

CMG-3TSensor Sensor type codeUnits (V/A)CMG-3T, 360s – 50 Hz responseCMG-3_360S_50HZ VCMG-3TB or 3V / 3ESP borehole,30s – 50 Hz responseCMG-3B_30S_50H

Seite 22 - Frequency response curves

Operator's guide3. Repeat this measurement for several tilt angles.4. For the vertical sensor, the input acceleration is given

Seite 23 - 3.3 Calibration with Scream!

Operator's guide1 IntroductionThe CMG-3T is a three-axis seismometer consisting of three sensors in a sealed case, which can measure

Seite 24

CMG-3T4 Accessories4.1 The breakout boxThis unit separates the lines in the signal cable, so you can connect a power supply, a recording system, and t

Seite 25

Operator's guideout, the instrument is ready for transportation.• To re-centre the sensor masses, hold down the ENABLE and CENTRE button

Seite 26

CMG-3Tvelocity output. There is also a RANGE switch allowing you to alter the sensitivity of the meter.CalibrationThe hand-held control unit can be us

Seite 27 - Sensor response codes

Operator's guide• the left-hand two sockets expose the balanced differential outputs representing ground velocity, and• the right-h

Seite 28 - 3.5 The coil constant

CMG-3T• To unlock the sensor masses, hold down the ENABLE and UNLOCK buttons simultaneously for one second. The BUSY LED will light.

Seite 29

Operator's guide5 Inside the 3T5.1 The sensorsThe horizontal and vertical sensors are similar in design. The inertial mass in both cases

Seite 30 - 4 Accessories

CMG-3TThe signal voltages output by the 3T are proportional to ground velocity and are transmitted from the instrument

Seite 31 - The meter

Operator's guideadjustment motors. It responds to commands sent on three input lines by grounding for 0.2 – 7 seconds.The signals you can send

Seite 32 - Control commands

CMG-3TThe five-stage process comprises locking the Z, N/S and E/W masses, followed by longer periods tilting the N/S and E/W sensor base to their

Seite 33

Operator's guideAgain, you can use the BUSY LED to monitor the progress of unlocking.1. The instrument checks to see

Seite 34

CMG-3TThe seismometer unit is self-contained apart from its 12 Volt power supply. Centring and mass locking can be carried out by

Seite 35 - 5 Inside the 3T

CMG-3Tsensor indicates an offset close to zero. In the case of the horizontal sensors, the sensor frame is tilted on its base plate.

Seite 36 - 5.2 The control system

Operator's guideactivating the CENTRE command again. You will probably need to initiate the centring process several times

Seite 37

CMG-3Twith OK. If there was a problem, such as one or more components failing to unlock or centre, the controller will report NG (“no good”.)L LockS

Seite 38

Operator's guideand damping of the sensor is completely determined by a feedback loop which applies a force to the sensor mass opposing any motio

Seite 39

CMG-3TThe hybrid feedback circuit contains a single capacitor in parallel with a resistor, resulting in a single dominant pole. Below this frequency,

Seite 40

Operator's guideThe conventional-response feedback system has an additional parallel feedback circuit, consisting of a non-inverting integrator i

Seite 42 - 5.4 The feedback system

Operator's guide6 Connector pin-outs6.1 Sensor and control unit pin outputModels with a 26-pin mil-spec plug (02E-16-26P) have the following pin

Seite 43 - Hybrid feedback

CMG-3Tc Power +veIn sensors with the RS232 control interface option, the RS232 ground line (pin H) is isolated from the other ground lines (pins Z and

Seite 44

Operator's guide26 RS232 ground (RS232 control interface option)In sensors with the RS232 control interface option, the RS232 ground line (pin 26

Seite 45 - Comparisons

Operator's guideAs an option, the 3T can be supplied with a 26-way “D”-type connector with standard pin assignments (see se

Seite 46 - 46 Issue N

CMG-3T9 RS232 receive at instrument (RS232 control interface option)10 Calibration signal (all channels)11 Calibration enable, N/S channel12 Calibrati

Seite 47 - 6 Connector pin-outs

Operator's guide7 SpecificationsHybrid sensors Velocity output bandwidth 0.1 – 50 Hz High pass filter output flat to acceleration0.01 Hz – spec*

Seite 48

CMG-3Tcentring (average) Current at 12 V DC during locking and unlocking490 mA†*spec refers to the quoted frequency response value, e.g., for a “30 s”

Seite 49

Operator's guide8 Revision history2009-07-06 N Added integrated SOH controller2006-10-19 M Added waterproof connector pin-out2006-08-14 L Added R

Seite 50

CMG-3TSensor responseThe 3T can be supplied with a response which is flat to velocity from 100 Hz to any of 0.1 Hz (10 seconds), 0.033 Hz (30 seconds)

Seite 51 - 7 Specifications

Operator's guide2 Installing the 3T2.1 First encountersUnpackingThe 3T seismometer is delivered in a single transportation case. The packaging is

Seite 52

CMG-3TSerial numberThe sensor's serial number can be found on the label stuck to the top lid of the sensor. It is also stamped onto the side of t

Seite 53 - 8 Revision history

Operator's guideboard ADCs.Breakout box and hand-held control unitThe 3T can be supplied with an optional robust breakout box, which provides m